The Solution:
Pure Ingenuity designed a return air plenum that involved a floor-level louvered door to pull the dirty air in, and two sets of HEPA filters within the plenum to make a safe filter system, as air was drawn up and out of the room through the floor-level grill in the plenum. The innovative design featured two filters in series with a sampling system in between that would instantaneously detect filter failure. When trace amounts of the hazardous powder were detected on the “filtered” side of the HEPA filters, the system immediately flagged the failed filter requiring replacement on the monitoring system. In order to bypass the time-consuming task of swapping out difficult-to-access HEPA filters, Pure Ingenuity designed a unique drawer-style easy-in, easy-out system that allowed the filter to be replaced in less than two minutes, with the use of a simple hand wrench tool only.

The Result:
As a result of the new design, the company met strict health and safety regulations, while ensuring minimal downtime in the event of a filter failure.